undefined
+
  • undefined

PRO-PLUS-UP(150-250LPH)

RO pure water: desalination rate as high as 95-99% , Conductivity ≤10μS/cm
Ultrapure water:
resistivity 18.25MΩ.cm@25°C,
TOC: <3 ppb,
particles (>0.22 um) <1/ml,
microorganism <1 cfu/m,
pyrogen<0.001EU/ml,
RNases≤0.01ng/ml,
DNases≤3Pg/ml/ul

  • Commodity name: PRO-PLUS-UP(150-250LPH)
  • Product Description
  • Specification

    Model No.

    Capacity

    Delivery time

    Warranty

    Payment term

    Remark

    PRO-PLUS-UP series

    150L/H

    200L/H

    250L/H

    7-10 working days after payment

    1 year

    T/T 100% in advance

     

     

    Product feature

    ➣ Ergonomic design, the machine is beautiful and generous in compliance with GLP requirements
    ➣ Fully automatic microcomputer control system, online water quality monitoring system, and filter element online monitoring
    ➣ New quick plug-in connector, filter column replacement and maintenance is more convenient for the electrical and water channels to be completely separated.
    ➣ Fully automatic RO membrane anti-fouling washing program and regular washing program to prolong the service life of RO membrane
    ➣ Power, water source, pump, flush, water shortage, full water status display, understand the machine running status
    ➣ Floor-standing design, with movable and fixed feet at the bottom, making installation and movement more convenient
    ➣ RO water, ultra pure water, two kinds of water outlets
    ➣ Free TDS water quality test pen

     

    Parameter

    PRO-PLUS-UP series ultrapure water machine

    Type classification

    Standard

    Low Endotoxin

    Low TOC

    Comprehensive

    The machine model

    PRO-PLUS-UP

    PRO-PLUS-UP-F

    PRO-PLUS-UP-V

    PRO-PLUS-UP-VF

    Water rate

    150/200/250 lph

    The water requirements

    Urban tap water, inlet water pressure: 0.15-0.5mpa, water temperature 5-40℃

    RO water Parameter

    Ion rejection rate

    97%-99% (when using a new RO membrane)

    Organic matter rejection rate

    >99% when MW>200 Dalton

    Particle and bacterial rejection

    > 99%

    UP water Parameter(ASTM TYPE I grade water)

    Resistivity (25℃)

    18.25 M Ω. Cm @ 25 ℃

    Heavy metal ion

    < 0.01 ppb

    Total organic carbon (TOC) *

    <10 ppb

    <3 ppb

    bacteria

    < 1 cfu/ml *(with terminal filter)

    Particulate matter (> 0.1 microns)

    <1/ml

    Pyrogen (endotoxin)

    N/A

    < 0.001 Eu/ml

    N/A

    < 0.001 Eu/ml

    Ribonuclease (RNases)

    N/A

    <1pg/ml

    N/A

    <1pg/ml

    Deoxyribonucleases

    N/A

    <5pg/ml

    N/A

    <5pg/ml

    Application

    All kinds of physical and chemical testing, biochemical analysis, blood examination, microanalysis, flushing special, HPLC, IC, GC, analysis experiment

    High sensitivity ICP/MS, PCR, PPT level analysis, isotope analysis, molecular biology, life science, CDC, drug control institute, quality inspection institute

    Atomic absorption/emission spectrometry, mass spectrometry, TOC detection, environmental monitoring, biochip development, trace organic matter analysis

    Molecular biology, Life sciences, gene research, cell culture, amino acid analysis, protein purification, toxicology, drug development, medical testing

    Electrical requirements

    100-240V, 50/60Hz, 48-72W

    The system configuration

    Host machine (including 1 set of purification column)+100L pressure water storage tank +TDS pen + accessory bag

     

    Process

    Filter function

    Product name

    Picture

    Function

    Replace cycle

    20’’ 5 μm PP cotton

    remove impurities (greater than 5 micron) such as suspended solid, rust, sludge, colloid, etc.

    About 4-6 month

    20’’ Refined activated carbon

    remove color, odor, residual chlorine and heavy metals

    About 4-6 month

    Reverse osmosis membrane

    filter out <1nm pollutants, ions, particles

    About 1-2 years

    Dual wavelength (185 & 254 nm) UV lamp (import)

    sterilization device, decomposition and photo oxidation OC, lower TOC  (*-V,-VF)

    About 9000 hours

    25L ultra purified tank

    ion exchange resin bed, H+ and OH- ion removal

    About 50 tons

    12’’ ultra purification column

    Imported 5000 Dalton UF heat source column

    remove pyrogen,RNase, DNase(*-F,-VF)

    About 2-3 years

    0.2μm terminal filter

    final removal for < 0.2μm bacteria

    About 2-3 years

     

    Machine SKU

    SKU

    Specification

    PRO-PLUS-UP-150

    150L/H, Standard type, RO pure water, UP ultra-pure water

    PRO-PLUS-UP-200

    200L/H, Standard type, RO pure water, UP ultra-pure water

    PRO-PLUS-UP-250

    250L/H, Standard type, RO pure water, UP ultra-pure water

    PRO-PLUS-UP-V-150

    150L/H, Low TOC type, RO pure water, UP ultra-pure water

    PRO-PLUS-UP-V-200

    200L/H, Low TOC type, RO pure water, UP ultra-pure water

    PRO-PLUS-UP-V-250

    250L/H, Low TOC type, RO pure water, UP ultra-pure water

    PRO-PLUS-UP-F-150

    150L/H, Low Endotoxin type, RO pure water, UP ultra-pure water

    PRO-PLUS-UP-F-200

    200L/H, Low Endotoxin type, RO pure water, UP ultra-pure water

    PRO-PLUS-UP-F-250

    250L/H, Low Endotoxin type, RO pure water, UP ultra-pure water

    PRO-PLUS-UP-VF-150

    150L/H, Comprehensive type, RO pure water, UP ultra-pure water

    PRO-PLUS-UP-VF-200

    200L/H, Comprehensive type, RO pure water, UP ultra-pure water

    PRO-PLUS-UP-VF-250

    250L/H,Comprehensive type, RO pure water, UP ultra-pure water

Keyword: