undefined
+
  • undefined

LAB-WP(10-30LPH)

RO pure water: desalination rate as high as 95-99% , Conductivity ≤10μS/cm
Ultrapure water:
resistivity 18.25MΩ.cm@25°C,
TOC: <3 ppb,
particles (>0.22 um) <1/ml,
microorganism <1 cfu/ml,
pyrogen<0.001EU/ml,
RNases≤0.01ng/ml,
DNases≤3Pg/ul

  • Commodity name: LAB-WP(10-30LPH)
  • Product Description
  • Specification

    Model Number

    Capacity

    Delivery time

    Warranty

    Payment term

    Configuration

    LAB-WP series

    10L/H

    20L/H

    30L/H

    7-10 working days after payment

    1 year

    T/T 100% in advance

    Machine+terminal filter+accessories kit

     

    Product feature 

    ➣ Colored touched screen, humanized operation interface make users completely monitor controller’s working status and real-time data.
    ➣ ABS engineering plastic case, powder coating technology, with water quality and quantity upgrading function, self-priming door.
    ➣ Type U Korean quick-insert filters, used imported filtering materials.
    ➣ Upgraded self-cleaning filter which with design of built-in 10’’ 10μm stainless steel filter mesh and silicone soft scraping, it can clean anytime, perfectly replace PP cotton filter, no need exchange.
    ➣ Long-acting KDF filter whose adsorption efficiency and lifetime are more than 10times as equal quantity activated carbon filter's, this avoid frequent filter replacement.
    ➣ Imported UF ultra filtration column ensure meet request for removing pyrogen and RNA.
    ➣ Built-in pressure tank which has inner pouch whose material is anti-bacteria and it is transparent, the inner pouch can be changed anytime.
    ➣ Inbuilt feed water pressure test gauge to real time monitor tap water pressure and filters blocking.
    ➣ Lifetime of PP cotton, activated carbon filter, RO membrane and ultra purification columns can be set to display the elapsed&rest time of consumables. Automatic reminder for filter replacement to avoid water quality decreasing.
    ➣ Perfect managing functions of RO&UP water making, circulation system and sterilization.
    ➣ Feed water, RO and UP water three ways water quality sensor and five ways switches signal are accessed integrated, with functions of timing quantitative water taking.
    ➣ Equipped with USB Host interface, it supports data export function of historical alarm record and historical water intake record.
    ➣ Low-voltage 24VDC is used as the main power supply, which meets the safety regulations and meets the requirements of humid environment, and will not cause personal injury.
    ➣ Can be with inner circulation system to ensure water quality keep at the highest level. ( optional)

     

    Parameter

    LAB-WP series ultrapure water machine

    Type classification

    Standard

    Low Endotoxin

    Low TOC

    Comprehensive

    The machine model

    LAB-WP

    LAB-WP-F

    LAB-WP-V

    LAB-WP-VF

    Water rate

    10/20/30 lph

    The water requirements

    Urban tap water, inlet water pressure: 0.15-0.5mpa, water temperature 5-40℃

    RO water Parameter

    Ion rejection rate

    97%-99% (when using a new RO membrane)

    Organic matter rejection rate

    >99% when MW>200 Dalton

    Particle and bacterial rejection

    > 99%

    Application

    Front system of ultra-pure water machine, buffer configuration, photosensitive film washing, water supply for stability experiment box, meteorological experiment equipment, hydrogen generator, battery adding liquid, electroplating and other instruments

    UP water Parameter(ASTM TYPE I grade water)

    Resistivity (25℃)

    18.25 M Ω. Cm @ 25 ℃

    Heavy metal ion

    < 0.01 ppb

    Total organic carbon (TOC) *

    <10 ppb

    <3 ppb

    bacteria

    < 1 cfu/ml *(with terminal filter)

    Particulate matter (> 0.1 microns)

    <1/ml

    Pyrogen (endotoxin)

    N/A

    < 0.001 Eu/ml

    N/A

    < 0.001 Eu/ml

    Ribonuclease (RNases)

    N/A

    <1pg/ml

    N/A

    <1pg/ml

    Deoxyribonucleases

    N/A

    <5pg/ml

    N/A

    <5pg/ml

    Application

    All kinds of physical and chemical testing, biochemical analysis, blood examination, microanalysis, flushing special, HPLC, IC, GC, analysis experiment

    High sensitivity ICP/MS, PCR, PPT level analysis, isotope analysis, molecular biology, life science, CDC, drug control institute, quality inspection institute

    Atomic absorption/emission spectrometry, mass spectrometry, TOC detection, environmental monitoring, biochip development, trace organic matter analysis

    Molecular biology, Life sciences, gene research, cell culture, amino acid analysis, protein purification, toxicology, drug development, medical testing

    Electrical requirements

    100-240V, 50/60Hz, 48-72W

    The system configuration

    Host machine (including 1 set of purification column)+8 L built-in pressure water storage tank +TDS pen + accessory bag

     

    Operation screen display

     

    Process(*LAB-WP-VF configuration)

     

    Filter consumables list

    Product name

    Picture

    Function

    Replace cycle

    Remark

    Front filter

    10 micron 316 stainless steel washable filter, remove minor impurities,extend PP cotton lifetime.

    /

     

    KDF composite filter

    Remove residual chlorine,heavy metals, retrain fungi breed, lifetime is very long, can protect post-positive filters.

    About 1 year

     

    11" PP filter

    remove impurities (greater than 5 micron) such as suspended solid, rust, sludge, colloid, etc.

    About 4-6 month

     

    11" activated carbon filter

    remove color, odor, residual chlorine and heavy metals

    About 4-6 month

    Reverse osmosis membrane

    filter out <1nm pollutants, ions, particles

    About 1-2 years

    10L/H--75 GPD RO membrane

    20L/H--150 GPD RO membrane

    30L/H--200 GPD RO membrane

    Dual wavelength (185 & 254 nm) UV lamp 

    sterilization device, decomposition and photo oxidation OC, lower TOC  (*-V,-VF)

    185nm: TOC removal

    254nm: sterilization

    About 9000 hours

     

    11" ultra-purification column

    ion exchange resin bed, H+ and OH- ion removal

    About 1000 liter/pc

     

    Imported 5000 Dalton UF heat source column

    remove pyrogen,RNase, DNase(*-F,-VF)

    About 2-3 years

     

    0.2 μm PES terminal filter

    final removal for < 0.2μm bacteria

    About 2-3 years

     

     

    User cases

     

    Machine SKU

    SKU

    Specification

    LAB-WP-10

    10L/H, Standard type, RO pure water, UP ultra-pure water

    LAB-WP-20

    20L/H, Standard type, RO pure water, UP ultra-pure water

    LAB-WP-30

    30L/H, Standard type, RO pure water, UP ultra-pure water

    LAB-WP-V-10

    10L/H, Low TOC type, RO pure water, UP ultra-pure water

    LAB-WP-V-20

    20L/H, Low TOC type, RO pure water, UP ultra-pure water

    LAB-WP-V-30

    30L/H, Low TOC type, RO pure water, UP ultra-pure water

    LAB-WP-F-10

    10L/H, Low Endotoxin type, RO pure water, UP ultra-pure water

    LAB-WP-F-20

    20L/H, Low Endotoxin type, RO pure water, UP ultra-pure water

    LAB-WP-F-30

    30L/H, Low Endotoxin type, RO pure water, UP ultra-pure water

    LAB-WP-VF-10

    10L/H, Comprehensive type, RO pure water, UP ultra-pure water

    LAB-WP-VF-20

    20L/H, Comprehensive type, RO pure water, UP ultra-pure water

    LAB-WP-VF-30

    30L/H,Comprehensive type, RO pure water, UP ultra-pure water

Keyword: